Alpha Technologies AlphaGen DCX2000 - Operator's Manual User Manual

Page 21

Advertising
background image

21

041-135-B0-001 Rev. A (07/2013)

3.0

Servicing, continued

3.3 Changing Oil

Engine oil is HOT! Avoid contact with skin and clothing.

WARNING! BURN HAZARD

Switch the engine OFF before draining the oil.

CAUTION!

Recommended oil is synthetic SAE 10W-40 when ambient temperature is above 32° F (0° C).
Synthetic SAE 0W-40 is recommended if operating temperatures are below 32° F (0° C).
Engine oil capacity: 15.2 fl oz (.45L)

Tools Required:

#2 Philips Head Screwdriver

Oil Drain Pipe

Drain the oil while the engine is still warm to assure thorough draining.

NOTE:

Procedure:

1. Remove the maintenance cover.
2. Remove the oil dipstick (use the slots in the oil drain pipe to easily remove the dipstick).
3. Install the oil drain pipe (included with the generator).
4. Drain the dirty oil into a container. Be sure to allow time for the oil to drain completely.
5. Refill with the recommended oil, ensuring the oil level is at the upper line on the dipstick.
6. Reinstall the dipstick and the maintenance cover and tighten the screws securely.

Dispose of used motor oil according to local environmental disposal regulations. Do not throw it in the trash or pour it on

the ground.

ATTENTION:

L

L/2

Fig. 3-2, Changing Oil

Dip Stick

Oil Fill Hole

Minimum

Oil Level

Maximum

Oil Level

Oil Drain Pipe