7 power supply installation – Alpha Technologies PWE-6FT User Manual

Page 34

Advertising
background image

34

031-259-B0-001, Rev A

2.7

Power Supply Installation

These instructions are included only as reference.

1.

Before installation; Inspect the power supply for damage, loose connectors, or other
potential failures. Correct discrepancies before proceeding.

2.

Place the XM Series 2 Power Supply on the appropriate enclosure mounting shelf. For the
PWE-6FT, it is the upper-right compartment of the enclosure.

3.

Switch the BATTERY BREAKER to OFF. This will prevent the inverter from starting when
the batteries are first connected to the XM Series 2 power supply.

4

Batteries are an important part of the XM Series 2 Power Supply. It is mandatory to properly
install and test all batteries, battery connections, and battery cables before connecting to
the power supply. For complete battery installation procedures, see Section 2.6.2 “Battery
Installation Procedure,” of this manual.

5.

After the batteries, battery connections, and battery cables have been verified to be in good
working order, plug the quick connects from the battery cable into the power supply’s
BATTERY INPUT connector. The connector is keyed and color-coded to fit in one direction
only.

6.

Plug the Remote Temperature Sensor into the TEMP PROBE connector located on the
Inverter Module assembly. Route the sensor end of the cable into the battery compartment.

7.

If the optional LRI lamp (Local / Remote Indicator) is included, plug the LRI cable into the
LRI connector.

8.

If status monitoring is used, plug the tamper switch into the 2-pin TMPR connector, and
plug the transponder cable into the connection on the transponder.

9.

Plug the connector from the SPI(s) into the module's “OUTPUT 1” and (optional) “OUTPUT
2” connector(s). Make sure that the SPI’s “ALT/ON” switch is in the ON position.

If the installation includes an ACI lamp option, plug the lamp’s connector into the module's “AC OUTPUT”; then
plug the SPI into the second connector on the ACI.

If the installation includes a Module Retaining Cable option, attach end of cable at hole provided in top rear
center of enclosure; then thread strap through XM Series 2 handle and clip strap back on itself.

10. Installation is complete. DO NOT switch ON the Inverter Module’s BATTERY BREAKER, or

apply AC power to the power supply. Refer to the power supply Operator’s Manual for Start-
up and Test procedures.

2.0

Installation, continued

Advertising