1xev-do – Atec Agilent-E4406A User Manual

Page 11

Advertising
background image

11

Modulation accuracy measurement (composite rho)

Composite rho is measure of the performance of a
cdma2000 transmitter’s modulation circuitry. Composite
rho can be measured for multichannel structure, i.e., a
pilot channel with multiple traffic channels.

Range at RF input

+30 to –50 dBm

EVM

Range

0 to 25%

Floor

2.0% or less for pilot only signal

Resolution

0.01% display resolution

I/Q origin offset

Range

–10 to –50 dBc

Resolution

0.02 dB display resolution

Frequency error

Range

±500 Hz

Accuracy

±10 Hz + transmitter accuracy
(nominal)

Resolution

±0.01 Hz display resolution

Intermodulation distortion

Range at RF input

+30 to –20 dBm

Input intermodulation

–20 to –65 dBc

power range

Relative accuracy

±1.5 dB

Resolution

0.01 dB display resolution

Spectrum emission mask measurement

Range at RF input

+30 to –20 dBm

Spectrum emission

–136 dBc/Hz at 1 MHz offset

power range

(nominal)

Relative accuracy

±1.0 dB

Resolution

0.01 dB display resolution

Occupied bandwidth measurement

Range at RF input

+30 to –20 dBm

Frequency

Resolution

1 kHz

Accuracy

±3 kHz

1xEV-DO

(Option E4406A-204)

Channel power measurement

1.23 MHz integration BW

Range at RF input

+30 dBm to –80 dBm

Absolute power accuracy for in-band signal
(excluding mismatch error), 18 °C to 30 °C

+30 to –28 dBm

±0.6 dB

at RF input

–28 to –50 dBm

±0.8 dB

at RF input

–50 to –80 dBm

±1.0 dB

at RF input

Power statistics CCDF measurement

Range at RF input

Maximum

+30 dBm (average)
+40 dBm (peak)

Minimum

–40 dBm (average)

Code domain measurement

For Pilot, 2 MAC channels, 16 channels of QPSK data

Code domain power

Range at RF input

+30 to –50 dBm (nominal)

Accuracy

±0.3 dB (nominal, spread

(Pilot, MAC, Data

channel power is within 20 dB

QPSK Data 8PSK)

of total power)

Advertising