Specifications
113
Loss/Length Specifications (cont.)
Specification OFTM-5612B
Multimode
Modules
OFTM-5732 Singlemode Modules
Maximum length measurement
5 km of 50
µ
m or 62.5
µ
m multimode
fiber
20 km of 9
µ
m singlemode fiber
Measurement range
1
2 km for Smart Remote and Loopback
modes
20 km for Far End Source mode
2
10 km for Smart Remote and
Loopback modes
60 km for Far End Source mode
2
Length measurement accuracy
±
1.5 m plus
±
2 % of length
±
1.5 m plus
±
2 % of length
Propagation time accuracy
±
15 ns plus
±
2 % of propagation time
±
15 ns plus
±
2 % of propagation time
Output power (nominal)
> -20 dBm minimum; -19.5 dB nominal
> -8 dBm minimum; -7 dBm nominal
Output power stability over 8-hour
period (after 5 minute warmup)
±
0.1 dB at 73 °F (23
o
C)
±
0.1 dB at 73 °F (23
o
C)
Detector type
InGaAs InGaAs
1.
Far End Source mode does not include length or propagation delay measurements.
2.
60 km at 1310/1550 nm on singlemode fiber, 20 km at 1300 nm on multimode fiber, 5 km at 850 nm on multimode fiber.