The Control display panel is mainly equipped with those functions
considered to be the basic functions required by an AC power sup-

Limit value Setting

The setting of limit values restricts the output setting range to pre-
vent damage to loads caused by operating errors.

Sensing Function

This function is useful when the load is located at a remote location
and it is desired to improve the stability of the voltage rms value at
that location (sensing point).
*Response characteristics, waveform distortion and other parameters
differ from the specifications of the PCR-L main unit during use of
the sensing function due to sudden changes in output stability and
load current.

Memory Function

Nine sets of output voltage and frequency settings can be stored in
memory. In addition, memory is backed up so that values that have
been written into memory can later be read out. Memory can be op-
tionally expanded to accommodate 99 settings.

Various Protective Functions

The PCR-L and LT series are equipped with the following protective
functions.

Functions<STANDARD>

plies. However, the panel can be given an even more professional
appearance by the optional addition of various expansion functions.

Key-Lock Function

This function prevents key operation thorough the control panel to
prevent set values from being changed by accident.

Measuring Functions

A full range of measuring functions contribute to greater work effi-
ciency.

❍: Standard functions
●: Optional functions (RC02-PCR-L / RS11-PCR-L / IB11-PCR-L)

RMS value

Voltage

Peak value

Average value (DC only)

RMS value

Peak value

Average value (DC only)

Peak hold value

Harmonic current

1st to 39 th harmonic

Effective electrical power

Apparent electrical power

Power factor

Electrical

Power

Current

Synchronous Function

This function allows the output voltage frequency and phase to be
synchronized to the frequency of the power source (50 / 60 Hz).

Self Test Function

This function performs self-diagnosis of the cause of abnormalities
when they occur (such as when a protective function is activated due
to an overload and so on).

Item

Function

Voltage

Set upper limit of output voltage

Set lower limit of output voltage

Frequency

Set upper limit of output frequency

Set lower limit of output frequency

Current

Output is interrupted when a current flows that is
in excess of the limit value

Internal Circuit
Protection

Load and
Internal Circuit
Protection

Input voltage range protective function

Overheating protective function

Internal circuit protective function

Overload protective function (current limit function)

Overload protective function (Internal semiconductor

protective function)

Photo shows display fully lit for catalog use.