(*1) Input range of 100V or 200V can be selected with a switch.
(*2) At an output voltage of 100V or 200V, output current rated value, load

power factor of 1 and output frequency of 40 to 999.9 Hz.

(*3) 100V or 200V range can be selected with switch on the front panel. Setting

resolution:0.1V

(*4) At an output voltage of 1 to 100V/2 to 200V and load power factor of 0.8

to 1 (AC mode).
At an output voltage of 100 to 150V or 200 to 300V (AC mode) as well
as at an output voltage of 100 to 212V or 200 to 424V (DC mode), the
output current is reduced in accordance with the output voltage.
At a load power factor or 0 to 0.8, the output current is reduced in
accordance with the load power factor (AC mode).
At an output frequency of 1 to 40 Hz, the output current is reduced in
accordance with the output frequency (AC mode).

(*5) For condenser input type rectified loads (restricted by the RMS value of

the rated output current).

(*6) Resolution: 1) 0.01 Hz (1.00 to 99.99 Hz)

2) 0.1 Hz (100.0 to 999.9 Hz)

(*7) At an output voltage of 80 to 150 V or 160 to 300V, a frequency of 10 to

999.9 Hz and a load power factor of 1.

(*8) Voltmeter, Ammeter : Effective in 40 to 999.9Hz at output setting.

Power Meter: Effective in 45 to 65Hz at output setting.

(*9) For true rms value display or waveform with a crest factor of 3 or less.

Model

PCR500L

PCR1000L

PCR2000L

PCR4000L

PCR6000L

Input Ratings (RMS Values)

Voltage

85 to 132V / 170 to 250V (100V or 200V range) (*1)

170V to 250V

No. of phase, Frequency

1

φ

, 47Hz to 63Hz

Apparent Electrical Power

Approx. 1kVA

Approx. 2kVA

Approx. 4kVA

Approx. 8kVA

Approx. 12kVA

Power Factor

0.95 typical (*2)

Current (100V or 200V range)

12A / 6A or less

24A / 12A or less

48A/24A or less

96A/48A or less

72A or less

Output Ratings - AC Mode (RMS Values)

Voltage

1 to 150V/2 to 300V (100V or 200V range) (*3)

Max. Current (*4)

5A/2.5A

10A/5A

20A/10A

40A/20A

60A/30A

No. of Phases

1

φ

Power Capacity

500VA

1kVA

2kVA

4kVA

6kVA

Max. Peak Current (*5)

4 times max. current (RMS value)

Load Power Factor

0 to 1 (advanced or delayed phase) (*4)

Frequency

1 to 999.9Hz(*4,6)

Output Voltage Waveform Distortion (*7)

Max.0.3%

Output Ratings - DC Mode

Voltage

1.4 to 212V/2.8 to 424V (*4)

Max. Current

2.5/1.25A

5A/2.5A

10A/5A

20A/10A

30A/15A

Power Capacity

250VA

500VA

1kVA

2kVA

3kVA

Voltmeter (RMS, PEAK,AVE) (*8, 9)

Indicators (Display Mode)

Ammeter (RMS, PEAK, AVE) (*8, 9)

Power Meter, Frequency Meter (*9)

Circuitry

Linear amp type

Dimensions

Main Unit

(W

×

H

×

D mm)

430

Ч

217

Ч

550

430

Ч

351

Ч

550

430

Ч

484

Ч

550

430

Ч

839

Ч

550

430

Ч

1105

Ч

550

Max. Projections

(W

×

H

×

D mm)

450

Ч

245

Ч

595

450

Ч

415

Ч

595

450

Ч

545

Ч

595

450

Ч

920

Ч

595

450

Ч

1190

Ч

595

Weight

Approx. 25kg

Approx. 49kg

Approx. 69kg

Approx.120kg

Approx. 160kg

Input/Output Terminal Board Connection Screws

Input Terminal Board

M4

M6

M6

M6

M6

Output Terminal Board

M4

M6

M6

M6

M6

0 to + 50

°

C/10 to 90% RH (no condensation of dew)

Operating Temperature and
Humidity Ranges

AC mode

DC Mode

Output Voltage Ratio (%)

Output Voltage Ratio (%)

100

80

60

40

20

0

0

20 40

60 80 100 120 140 150

Output Current Ratio(%)

Output Current Ratio(%)

100

80

60

40

20

0

0

40

80

120

160

220

200

Load Power Factor

Output Frequency (Hz)

100

80

60

40

20

0

1

0.8

0.6

0.4

0.2

0

Output Current Ratio (%)

Output Current Ratio (%)

100

80

60

40

20

0

1 10 20 30 40 50

999.9

Output Voltage Ratio - Rated Output Current Characteristics

Load Power Factor
- Rated Output Current
Characteristics

Output Frequency
- Rated Output Current
Characteristics

Specifications

PCR-L series

MULTI PURPOSE AC POWER SUPPLY (CV·CF)

Advertising