Pcr-l series, Multi purpose ac power supply (cv·cf), Options – Atec Kikusui-PCR500L User Manual

Page 8

Advertising
background image

Page8

Copyright © 2002 KIKUSUI ELECTRONICS CORP. All rights reserved.

http://www.kikusui.co.jp/

■

Remote Controller (RC02-PCR-L)

The remote controller allows each of the functions on the
control panel of members of the PCR-L/LT series to be
manipulated while away from the control panel. Moreover, this
remote controller is composed of options for expanding
functions, including harmonics
current analysis, power line
irregularity simulation and
sequence operation, a remote
controller box a remote
controller card (inserted into a
slot in the main unit) and a
remote controller cable

(length:2m).

■

GPIB Interface(IB11-PCR-L)

The GPIB interface for the members of the
PCR-L/LT series allows programmable control
of the functions on the power supply control
panel as well as nearly all the expansion
functions available by using the RC02-PCR-L
remote controller. This interface also performs

readout of measured values.

■

RS-232C Interface (RS11-PCR-L)

The RS-232C interface for the PCR-L/LT
series allows readout of measured values and
programmable control of the functions on the
power supply control panel as well as nearly
all the expansion functions available by using
the RC02-PCR-L remote controller.

■

Centrally Controlled Parallel Operation Driver

(PD02M-PCR-L/PD02S-PCR-L)

This option card is for expanding the

output capacity of members of the
PCR-L series by means of parallel
operation. This card is applicable to the
combinations shown at right.
*Some modification may be required
depending on the version of the power

supply main unit.

Note: In this application, the ROM version of the PCR-L series

must be Ver.2.00 or later.

■

Three-Phase Output Driver (3P02-PCR-L)

This option card is for
expanding the output of
members of the PCR-L series
to a three-phase output. This
card is applicable to the
combinations shown at right.
*Some modification may be
required depending on the
version of the power supply
main unit.

Note1: In this application, the ROM version of the PCR-L se-

ries must be Ver.2.00 or later.

Note2: The following functions are not available when the 3-

Phase Driver is installed.

•

Power Line Irregularity

•

Simulation function

•

Current limit

value setting

•

Average voltage/current value measurement

•

Sens-

ing function

•

Regulation Adjustment function

•

DC Mode

•

AC

+ DC Mode

AC Output

✔

✔

✔

DC Output

✔

✔

✔

AC + DC Output

✔

✔

Harmonics Current Measurement

✔

✔

Power Line Irregularities Simulation

✔

✔

Sequence Operation

✔

✔

Special Waveform Output

✔

✔

User Defined Waveform Output

✔

Output ON/OFF Phase Setting

✔

✔

Output Impedance Setting

✔

✔

Memory Size (No, of Sets of Settings)

9

99

99

Regulation Adjustment

✔

Measurement Functions

RMS Value

✔

✔

✔

Output

Peak Value

✔

✔

✔

Average Value (DC Only)

✔

✔

✔

RMS Value

✔

✔

✔

Current

Peak Value

✔

✔

✔

Average Value (DC Only)

✔

✔

✔

Peak Hold Value

✔

✔

Electrical

Effective Electrical Power

✔

✔

✔

Power

Apparent Electrical Power

✔

✔

Power Factor

✔

✔

Other Functions

✔

✔

✔

Function

Power Supply

Only

Power Supply
+ RC02-PCR-L

Power Supply
+ IB11-PCR-L
or RS11-PCR-L

Combinations Required for Single-Phase Parallel Operation

PCR500L PCR1000L PCR2000L PCR4000L PCR6000L 3P02-PCR-L

PD02M-PCR-L

1.5kVA

3

1

3kVA

3

1

6kVA

3

1

12kVA

3

1

12kVA

6

1

3

18kVA

3

1

18kVA

9

1

3

24kVA

6

1

3

36kVA

6

1

3

36kVA

9

1

3

54kVA

9

1

3

Combinations Required for Three-Phase Parallel Operation

Note:Please inquire separately regarding parallel operation using 4 or more power supplies.

Output

Capacity

Parallel Operation

Driver

Three-Phase

Driver

Model

Options

Model

Parallel Operation Drive

PCR2000L

PCR4000L

PCR6000L

PD02M-PCR-L PD02S-PCR-L

4kVA

2

1

1

6kVA

3

1

2

8kVA

2

1

1

12kVA

3

1

2

12kVA

2

1

1

18kVA

3

1

2

Output

Capacity

PCR-L series

MULTI PURPOSE AC POWER SUPPLY (CV·CF)

Note:Please inquire separately regarding parallel operation using 4 or more power supplies.

Advertising