5 remote operation, Remote operation – B&K Precision 1747 - Manual User Manual

Page 19

Advertising
background image

17

5 Remote Operation

The power supply can be connected to the RS232 interface using the 9-pin (DB-9)
serial connector on the rear panel. The 1747 uses a null modem RS232 cable. The
cable pin diagram for the DB-9 connector is shown in the picture below:

2

3

5

RX

TX

GND

DB-9

connector

Instrument

2

3

5

RX

TX

GND

PC

DB-9

connector

Figure 10 - RS232 Cable Pin Diagram

For all communications over the RS232 interface, the power supply uses Xon/Xoff
protocol.

NOTE: If using HyperTerminal, make sure you properly configure the “ASCII Setup”. In
“ASCII Setup”, do not append line feeds to “ASCII Sending”. “Echo typed characters
locally” can be checked, but “Send line ends with line feeds” should be left
unchecked. In “ASCII Receiving”, “Append line feeds to incoming line ends” can also
be checked.