8 specifications, Specifications – B&K Precision 1747 - Manual User Manual

Page 32

Advertising
background image

30

8 Specifications

1747

Output Ratings ( 0 °C~40 °C)
Voltage

0-60 V

Current

0-10 A (0-35 V),

0-5 A (35-60 V)

Load Regulation ±(% of output+offset)
Voltage

0.01% + 5 mV

Current

0.2% + 3 mA

Line Regulation ±(% of output+offset)
Voltage

0.01% + 3 mV

Current

0.2% + 3 mA

Ripple & Noise (20 Hz ~ 20 MHz)
Voltage

1 mVrms

Current

≤ 3 mArms

Recovery Time

≤ 100

μs

Meter Resolution
Voltage

10 mV

Current

1 mA (0-5 A)

10 mA (5-10 A)

Meter Accuracy
Voltage

0.5% + 5 digits

Current

0.5% + 5 digits

General
Power Requirements

115/230 VAC ±10%, 50/60 Hz

Power Consumption

≤ 560 W

Protection

Reverse polarity, current limiting

Operating Environment
Temperature

32 °F to 104 °F (0 °C to 40 °C)

Humidity

75% R.H.

Temperature coefficient (0 °C~35 °C)

±(%of output+offset)

300 ppm/°C

Advertising