1 rs232 configuration overview, 2 rs232 commands, Rs232 configuration overview – B&K Precision 1747 - Manual User Manual
Page 20: Rs232 commands
Advertising

18
5.1 RS232 Configuration Overview
Baud Rate
9600 bps
Parity Bits
none
Data Bits
8
Start Bits
1
Stop Bits
1
Flow Control
Xon / Xoff
Termination Character
\r
Table 1 - RS232 Configuration
5.2 RS232 Commands
NOTE: All commands are case sensitive and must be capitalized.
1.VOLT xx.xx<CR>
This command sets the output voltage value. The output voltage takes the
programmed value only if the power supply is in Constant Voltage mode.
Example: The output voltage is set at 5 V.
VOLT 05.00<CR>
2. CURR x.xxx<CR> or CURR xx.xx<CR>
This command sets the output current value. The output current takes the
programmed value only if the power supply is in Constant Current mode.
Advertising