5.1 RS232 Configuration Overview

Baud Rate

9600 bps

Parity Bits

none

Data Bits

8

Start Bits

1

Stop Bits

1

Flow Control

Xon / Xoff

Termination Character

CR (0x13)

Table 1 - RS232 Configuration

5.2 RS232 Commands

Note : All commands are case sensitive, therefore be sure all letters are
CAPITALIZED before sending it to the instrument.

1.VOLT xx.xx<CR>

This command sets the output voltage value. The output voltage takes the
programmed value only if the power supply is in Constant Voltage mode.

Example: The output voltage is set at 5V.

VOLT 05.00<CR>

2. CURR xxx.x<CR>

This command sets the output current value. The output current takes the
programmed value only if the power supply is in Constant Current mode.

Example: The output current is set at 300mA.