B&K Precision 1739 - Manual User Manual
Page 22

20
CURR 3000.0<CR>
3. VOLT?<CR>
This command returns the voltage measured to the output terminals of the
power supply: xx.xxV<CR>
The voltage value returned is the same as the one displayed on the voltage
display.
4. CURR?<CR>
This command returns the current measured to the output terminals of the
power supply: xxx.xmA<CR>
The current value returned is the same as the one displayed on the current
display.
5. STAT?<CR>
The power supply responds to this command with one of the following
messages:
CV<CR> if the power supply is in Constant Voltage mode
CC<CR> if the power supply is in Constant Current mode
6. OUT ON<CR>
Turn output power on.
7. OUT OFF<CR>
Turn output power off.
8. IDN?<CR>