20

CURR 3000.0<CR>

3. VOLT?<CR>

This command returns the voltage measured to the output terminals of the
power supply: xx.xxV<CR>

The voltage value returned is the same as the one displayed on the voltage
display.

4. CURR?<CR>

This command returns the current measured to the output terminals of the
power supply: xxx.xmA<CR>

The current value returned is the same as the one displayed on the current
display.

5. STAT?<CR>

The power supply responds to this command with one of the following
messages:

CV<CR> if the power supply is in Constant Voltage mode

CC<CR> if the power supply is in Constant Current mode

6. OUT ON<CR>

Turn output power on.

7. OUT OFF<CR>

Turn output power off.

8. IDN?<CR>

The power supply responds with: “B+K PRECISION 1739 Revision x.x <CR>”.