4.3.2 Disconnection

WARNING: Wrong disconnect sequence will damage the power supply.

1. Disconnect the remote sensing connections.

2. Disconnect the power connections between the power supply and

equipment.

4.4

Analog Remote Control


There are two methods to remote control voltage and current.

Note: Both methods require the remote control connector plug to be set up in order
for analog remote control mode to be functional; otherwise the unit will be in CC
mode all the time.

4.4.1 Voltage Remote Control

Set up the provided remote connector plug.

(a)

Remove the black portion of the remote control connector plug by removing

the screw as shown in

Figure 4

.

Figure 4 - Remote Control Connector

(b)

Solder 5 wires (22AWG) to pins 1, 2, 3, 4, and 5 of pin plug. Refer to

Figure 5

for pin numbers.