Warning: luminaire must be earthed – Dialight WP SERIES DuroSite Wallpack / Bulkhead Luminaire User Manual

Page 2

Advertising
background image

Dialight – LED Solutions for Industrial and Hazardous Applications

Tel: +44 (0)1638 665161 – Fax: +44 (0)1638 660718 –

www.dialight.com

WARNING: LUMINAIRE MUST BE EARTHED


7. Check all connections are correct and there are no loose or un-terminated cables, replace LED tray ensuring that no cables
or that the drop cord is trapped, DO NOT OVERTIGHTEN. When complete re-connect the power supply and test for
operation.

IMPORTANT NOTE TO THE INSTALLER

THESE INSTRUCTIONS CONTAIN IMPORTANT SAFETY INFORMATION, PLEASE ENSURE THAT A COPY IS MADE
AVAILABLE TO THE USER AND/OR MAINTENANACE ENGINEER OF THESE PRODUCTS.

Specification:-

Tightening torques:-

Supply Voltage

100-277VAC 50-60Hz

Front assembly to body

2.0Nm / 18.0 in lb

Supply Current

100mA @ 230VAC / 200mA @ 100VAC

Bracket to body

8.0Nm / 71.0 in lb

Operating Temperature Range

-40°C to +60°C

Input Terminal Block Capacity

0.5

2

– 4mm

2

/ 18-14 AWG

Additional cable gland if required

M20 x 1.5

Weight

4.5Kg / 10.0 lbs

(to IP 66 rating)

Maximum loop current

16A

Rated fuse/circuit breaker

Consult MCB manufacturer

Fig.1

Fig. 2

Fig. 3

Fig. 5

Fig. 4

Multiple Fixture Connection Example

Fig. 6

Mains Input Connection

Mains Input Connection