Pendent Mount Installation Steps:
•
For maximum long term reliability and light output, the light must be installed in free air.
o
The High Bay fixture design incorporates an over-temperature control circuit that
reduces input power should internal temperatures reach a maximum level. As a
result, light output may be reduced.
•
The High Bay fixture is threaded for 3/4” NPT in order to be assembled to conduit.
o
Calculate and measure required conduit length.
o
Feed the power cable through the conduit and into the junction box.
o
Attach the fixture to the conduit (using Teflon tape or pipe sealant).
o
Insert 1/4-20 set screw in order to secure the fixture to the conduit.
•
Connect power cable conductors as follows:
o
For single phase (347 VAC):
Green wire connects to Safety Ground.
White wire connects to Neutral
Black wire connects to Live
o
For two phase (480 VAC):
Green wire connects to Safety Ground.
Black wire connects to Line 1.
White wire connects to Line 2.
•
Restore power and verify operation.
3: Maintenance
•
To avoid personal injury, disconnect power to the light and allow the unit to cool down
before performing maintenance.
Warning: No user serviceable parts inside of fixture. Risk of electric shock. Removal of the
lens will void the warranty.
1) Perform visual, mechanical and electrical inspections on a regular basis. We recommend
routine checks to be made on a yearly basis. Frequency of use and environment should
determine this. It is recommended to follow an Electrical Preventive Maintenance Program
as described in NFPA 70B: Recommended Practice for Electrical Equipment.