Inputs Connections

PWAR & AR111

Maximum Input Current 700mA
Maximum Cable Diameter 0.5²mm
Thermistor Protection* 10K
Maximum Cable Diameter 1.5mm² / 16 AWG

*Thermistor connection optional and not polarity sensitive, connection not
required unless external driver has thermistor control.

PWARD & AR111-LV

Maximum Input Voltage 12-24 VDC / 11-16 VAC
Maximum Cable Diameter 1.5mm² / 16 AWG
Dimming Input Consult Factory

Environmental PWAR & AR111

Operating Ambient Temp. -20°C to +40°C
Operating Case Temp. Max. -20°C to +85°C at 700mA
-20°C to +105°C at 350mA
Ambient Storage Temp. -40°C to +100°C
MTBF (@ 40°C) 50K Hours

Environmental PWARD & AR111-LV

Operating Ambient Temp. -20°C to +40°C
Operating Case Temp. Max. -20°C to +75°C
Ambient Storage Temp. -40°C to +100°C
MTBF (@ 40°C) 50K Hours

Mechanical PWAR & PWARD


Casing ADC10 Aluminium Alloy
Finish Anodised Satin Silver
Connection Cage Clamp Connectors
Dimensions mm [inches]

Mechanical AR111 & AR111-LV

Module as PWAR/PWARD.

Heat sink material ADC10 Aluminium Alloy
Heat sink finish Black Anodised
Connection Cage Clamp Connectors
Dimensions mm [inches]

Mounting and Cooling AR111 & AR111-LV Units

1.

The AR111 and AR111-LV modules are supplied complete with their own approved designed heat sink this as a full assembly can be fitted into a

majority of AR111 compatible light fittings.

2.

The ready-assembled units are suitable for operation in a 40°C ambient and at 700mA for the constant current unit.

3.

Always keep the heat sink fins clear and provide the unit with adequate ventilation.

1.

The PWAR and PWARD modules require an additional heat sink for full power
operation, the heat sink cooling should maintain a maximum case temperature
‘Tc’ under the worst case conditions.

2.

Thermal performance of third party heat sink designs should be confirmed by
a thermocouple temperature measurement as near to the ‘Tc’ point of the
module case.

3.

Heat sink performance required depends upon operating current, maximum
ambient expected and lifetime trade offs, for 50,000 hours lifetime, minimum
heat sink performance, see table :-

Max Ambient °C

20

30

40

50

60

350mA

7.9

6.9

6.0

5.1

4.2

700mA

2.9

2.4

2.0

1.6

1.1

On-board Driver

4.4

3.5

2.6

1.8

0.9

Mounting and Cooling PWAR & PWARD Units

Heat sink performance in °C/W

A55-PWAR-INST-ISSUE01

Do


1

DO make sure that the heat sink used for the module is adequate for
the operating conditions, failure to observe this could result in lower

performance, reduced life of the module or permanent damage.

2

DO observe polarity when connecting the modules to the power
source.

3

DO use the cable strain relief on the rear of the unit where possible.

4

DO allow adequate airflow and ventilation when installing the

LED modules.

Don’t


1

DO NOT use outdoors, modules are for indoor use only.

2

DO NOT cover with any insulation material that could restrict any
airflow and cooling.

3

DO NOT use cable crimps or ferrules as this can damage the

cable-clamp connectors.

4

DO NOT allow the unit to be exposed to moisture.