Motec data loggers, 20 operation, Config status – MoTeC LTCN User Manual

Page 20: Firmware version, Configure data logger communications for ltc

Advertising
background image

20

Operation

Any LTC unit configured with a CAN address within the 15 CAN addresses
following a Collect Master address will be shown as Slave (x).

The number in the collect column (e.g. (3)) refers to the LTC number (1 to 16)
in the messages transmitted by a Collect Master LTC.

For more information about CAN Collect, see

CAN Collect Functionality

Config Status

The Config Status column shows any issues relating to the configuration of the
connected LTCs.

Config Status

Description

OK

Config is OK

Disabled

The LTC has been disabled under the Setup options.

A disabled LTC will not measure or transmit readings.

Incompatible
Config

The configuration in the LTC is not compatible with
the firmware in the LTC. A new configuration can be
sent to the LTC by changing the Setup or Calibration.

Corrupt Config

The configuration in the LTC is corrupt. A new
configuration can be sent to the LTC by changing the
Setup or Calibration.

CAN Address
Conflict

Multiple LTC units have been configured with the
same CAN address. Each LTC must be configured
with a unique address.

Firmware Version

The Firmware Version column shows the version of the firmware in each of the
connected LTCs.

MoTeC Data Loggers

MoTeC Data Loggers SDL, SDL2, ADL2, ADL3 and ACL include CAN
communication templates to receive LTC messages from up to 16 LTCs.

Received Lambda readings and diagnostics can be displayed and logged.
Refer to the Dash Manager software for more information.

Configure Data Logger Communications for LTC:

• Select Inputs > Communications