Motec configuration 9, Ltc unit setup – MoTeC LTCN User Manual

Page 9

Advertising
background image

MoTeC

Configuration

9

LTC Unit Setup

To open the LTC Setup window, double click the row in the table
containing the LTC or click the row and click Setup.

Select the Recommended Address check box and enter one of the
addresses in the drop down box to communicate with MoTeC products
such as Data Loggers or 'hundred series' ECUs.
The recommended address range for LTC messages is hex 460 to hex
47F.

OR

Select the Custom Address check box and enter an address (in hex) for
interfacing with third party equipment.

OR

Select Disabled to prevent an LTC from transmitting CAN messages.
While disabled an LTC will not heat the sensor or perform Lambda
measurements.

Note: Lambda sensors should not be left in the exhaust system of a
running engine if they are not being controlled. A disabled sensor in a
running engine can be damaged.

In the Name area the default name will appear. The default name matches
the selected CAN Address (LTC1 etc.). If required the user can specify a
custom name (e.g. Left Bank or Cylinder 4).

Tip: The rows in the main LTC Manager window are sorted by the Name
column.