MoTeC

Installation

5

Place the sensor at least 1 meter from the open end of the exhaust system
to avoid incorrect readings due to outside oxygen (recommended)

o

Where necessary for shorter exhaust systems the sensor could be

placed closer to the engine.

Place the sensor away from the flame front coming out of the cylinder head
and away from areas where one cylinder may have more effect than
another.


If possible, do not place the sensor near exhaust slip joints; some designs
allow air to enter resulting in incorrect readings.
If the sensor has to be placed near a slip joint, reverse the slip joints to
reduce the influence of introduced air.

Exhaust slip joint design

Exhaust flow

Introduced air

No air introduced

Incorrect sensor
placement

Correct sensor placement