Foot Switch

Designed to work in series with the Safety Switch, the Foot Switch is a simple mechanical
micro-switch operated by a spring-loaded pedal. At rest the switch condition should be normally
open. Closing the switch begins the cycle.

ƒ Turn the power to the machine off.

ƒ Turn the Foot Pedal and guard over and remove the two small screws that hold the pedal

to the base.


ƒ Use a flat tip screwdriver to pry the pedal free from the yellow guard (it is held by a

silicone caulk).

ƒ Using a flat or phillips screw driver, remove the two screws on the left and right side of

the pedal. This will allow the pedal to come apart exposing the switch underneath.


ƒ Use two leads of the ohmmeter to probe the wire terminals while the switch is still in the

pedal. (Figure 25)

Figure 25

ƒ Without depressing the spring plate, the switch should register as an open circuit. When

depressing the plate, the switch should register as a closed circuit (approximately 0
ohms).

ƒ If an open circuit is still registered, then a new switch should be installed.