6.3 - BALANCING MACHINE CALIBRATION
►
To calibrate the machine, operate as follows:
Fit a medium-sized wheel with steel rim on the shaft. Example: 6” x 15” (± 1”) best with less then 20 g unbalance
■
Take the exact measurements of the wheel mounted as described in
■
DATA SETTING
.
P
RESETTING
OF
INCORRECT
DIMENSIONS
WOULD
MEAN
THAT
THE
MACHINE
IS
NOT
CORRECTLY
CALIBRATED
,
THEREFORE
ALL
SUBSEQUENT
MEASUREMENTS
WILL
BE
INCORRECT
UNTIL
A
NEW
SELF
-
CALIBRATION
IS
PERFORMED
WITH
THE
CORRECT
DIMENSIONS
!
Perform a manual spin under normal conditions
■
Add a sample weight on the outside in any angular position.
■
Sample weight:
60 g. (2.00 .oz) for car
300 g. (10.0 .oz) for truck
Perform a manual spin
■
Shift the sample weight from the outside to the inside keeping the same angu
■
lar
position.
Perform a manual spin
■
Turn the wheel until the sample weight is in the 12 o’clock position
■
END OF CALIBRATION
■
CANCELS CALIBRATION IN ANY PHASE.
■