CEMB USA C72_2 (A) User Manual

Page 13

Advertising
background image

I 0459 -

13

9a

10

GB

Position of the counterweights proposed automatically when the difference in the
diameters dI, dE is less than 2”.

Position of the counterweights proposed automatically when the difference in the
diameters dI, dE is greater than or equal to 2”.

After performing a balancing spin, the amounts of unbalance are shown on the digital readouts.
The matrix displays indicate the correct angular wheel position to mount the counterweight

s

(12 o’clock position).

When the beep signal is enabled (see section

CONTROL OF THE FUNCTIONS MENU

), this is activated when the wheel

reaches the correction position.

If the unbalance is less than the threshold selected,

is displayed instead of the unbalance, with

it is possi-

ble to read the values below the threshold chosen gram by gram.

If the static unbalance is greater than 30 g, the LED

flashes to suggest an unbalance optimisation operation

(chapter

UNBALANCE OPTIMISATION

).

With the button

it is in any case possible to select the type of ALU desired.

5.4 - Result of measurement

Inside correction

Outside correction

Advertising