E40 mm – CEMB USA C71 (B) User Manual
Page 16
Advertising
40 mm
40 mm
I 0378 -
16
I 0378 -
17
GB
GB
6.5.2 - Diameter gauge
E40 mm
Place the round part of the gauge terminal on the fl ange as shown in
the fi gure and press
.
- The number 353 ± 1° appears on the left display .
- Turn the gauge downward position the round part of the gauge
terminal at 40 mm (radial distance) from the fl ange as indicated
in the fi gure.
- The number 256 ± 3° should appear on the left display.
- If not, press the button
holding the gauge still at 40 mm: the
number 256 appears on the left display.
- Return the gauge to rest position.
In the event of incorrectly accessing the diameter gauge calibration
function, press
S�T�O�P�
to cancel it.