CEMB USA C71_2 (B) User Manual

Page 4

Advertising
background image

2

2a

3

A

B

I 0539 -

4

GB

3 - Startup

3.1 - Anchoring

The machine can operate on any flat non resilient floor.
Make sure that the machine rests solely on the three support points provided (Fig.2a).

3.2 - Electrical connection

The machine is supplied with a single-phase mains cable plus earth (ground).
(any extension cables must have a cross-section of no less than 2.5 mm

2

).

The power supply voltage (and mains frequency) is indicated on the machine identification plate and cannot be
changed. Connection to the mains must always be made by expert personnel.
The machine must not be set up without proper earthing.
Connection to the mains should be through a slow acting safety switch rated at 16 A (230V) or 40A (115V). See enclosed
diagrams.

3.3 - Flange mounting

2 - Handling and lifting

The wheel balancer is supplied complete with cone flanges
for fixing wheels with a central hole. To mount other optional flange
adaptors :

a) Remove the threaded end-piece A after unscrewing the screw B.

b) Mount the new flange (see attached sheets).

NOTE: CAREFULLY CLEAN THE COUPLING SURFACES BEFORE

PERFORMING ANY OPERATION.

3.4 - Wheel guard assembly and adjustment (optional)

a)

Fix the components to the base as described in the attachment

WHEEL GUARD ASSEMBLY SEQUENCEat

the end of the manual.

Note: Do not lean on the guard during the wheel balancing cycle.

NOTE: DO NOT LIFT THE WHEEL

BALANCER USING OTHER GRIPS.

Advertising