A- settings in mixer mode – Analog Way OPS300 User Manual

Page 32

Advertising
background image

30

To set up your inputs:

Input menu → Auto settings

You can also do it manually on each input# using the

[

ENTER

]

and the Knob button and set up the inputs

type one by one.

You can also check your actual input configuration using the config status:

Input menu → Config Status

You can find several settings for each input (some settings are specific to some signal type):
-

Type:

to set up your input type (Computer, Video etc..)

-

Enabled/disabled:

to enable/disable input#

-

Audio input:

to set up the audio regarding the input

-

H sync. load:

to change the load of the Sync. signal (Hi-Z, 75 ohms)

-

EDID:

to set up the EDID in terms of resolution and rate

-

Status:

to summarize the input status

Concerning the DVI inputs, a specific feature allows enable/disable the HDCP receiver for the input chosen.

It can be very useful especially using a Mac:

Input menu → DVI # → HDCP detection

* NOTE * : the input status is available at any time in status input menu and can give you information about

format rate and HDCP.
If you have any trouble to detect source, please check the Input status and see if the unit is receiving a source

or not.

Input selection settings

Source Input selection

Plug your sources thanks to the 8 universal inputs, 2 DVI-I Inputs or 2 SDI inputs.

Don’t forget that the 2 DVI-I inputs can be used with DVI-D computer sources (DVI

#

1 & DVI

#

2) but also with

a DVI-I adaptor for analog sources too (source #5 & #6) shipped with your unit.

Be sure that all connectors are firmly attached using all available locking screws.

A- SETTINGS IN MIXER MODE

Input Sync. Loss Function

The Input Sync. Loss function allows to display a source in case of sync loss of the selected input. To set up

the Sync. Loss function:

Menu → Control → Sync. Loss → Press Input#

The selected input must be activated to be visible in case of sync loss.

Advertising