IIf you need to use your own Software Control program from a PC

or automation, the device allows communication through an ASCII

code protocol. All commands can be downloaded on our website

.

All Analog Way products equipped with an RS232 input are

compatible with Crestron, AMX, Medialon, and most major control

systems. TCP/IP control ports are also available on most Analog

Way products, as standard or as options.

To control an

SVU200

product with an External Remote Controller

(PC Software Control - Touch Pad Controller…) follow the indications

below :

1/ First establish an RS-232 communication between the Remote

Control Software and the

SVU200

, in order to setup the LAN

parameters of the product.

2/ In the “Control” - “SmartVu LE LAN Setup” menu, configure the

connection of the

SVU200

product in UDP mode and setup the Local

and Remote Addresses as well as the Local and Remote Ports in

concordance with your Network.

3/ Configure the TCP/IP address of your External Remote Controller.

In example: 192.168.000.001

4/ Setup the UDP connection of your External Remote Controller in

concordance with your Network.

In example on the Remote Software in the “Control” - “RS232/LAN

Setup” - “LAN/Setup” menu :

5/ Setup the LAN parameters in UDP mode in the “Console” - “LAN

Setup” menu.

In example:

RK Address:

192.168.000.002

Remote

Address:

192.168.000.010

Gateway

Address: 192.168.000.001

RK

Port:

10500

Remote

Port:

10500

Netmask:

255.255.255.000

6/ Select the LAN communication port in the remote controller

console - “RS232/LAN port” menu.