Datamax-O'Neil A-Class Mark II Operator’s Manual User Manual

Page 90

Advertising
background image

80

A-Class Mark II

Step

Action

Displayed Message

Comment

K

In the table, where both

the Label Value and TOF
Value are at least 20,

subtract the amounts and
record the result as a
Difference Value (see

below).

Identify the largest
Difference Value and then

the corresponding Gain
Number.

GAIN TRAN

*31 (0 - 31)
<yyy>

- Or, for reflective media:

GAIN REFL

*31 (0 – 31)

<yyy>

•

In this example, Gain

Number 18 is chosen

because, where both values
are at least twenty, it has

the highest Difference Value.

•

This Gain Number will be

used to resample the media.

Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252 248 4
01 250 245 5
02 248 234 14

… … … …

15 188 63 125
16 184 51 133
17 179 38 141
18

174

25

149

19 170 19 N/A

… … … …

31 132 14 N/A


Step

Action

Displayed Message

Comment

L

Scroll to the Gain Number

determined in the
previous step and then

press the ENTER Key.

GAIN TRAN

*18 (0 - 31)
<yyy>

- Or, for reflective media:

GAIN REFL

*18 (0 – 31)

<yyy>

After ENTER is pressed, an

asterisk (*) appears to denote
selection.

(Continued)