Input power and connection requirements – Datamax-O'Neil VMP-2000 Installation Guide User Manual

Page 10

Advertising
background image

8

Input Power and Connection Requirements

Datamax-O’Neil VMP-2000 Installation Guide

Input Power and Connection Requirements

The VMP printer comes with one 12 volt DC jack cable with white collar or tag (external).

1

The mating connection to the VMP printer is a DC plug, 2.5mm x 5.5mm x 11 or

12.0mm in length.

2

The center pin on the plug is positive (+). The center pin on the barrel is negative (-).

3

If a molded DC plug cable is purchased to connect to the printer, limit its length to 12

inches, due to voltage drops.

Cable

Power applied

12 volt white cable
(primarily used in
vehicles)

Unit will run from vehicle power; however, it could reset if there are voltage dips and fluctua-
tions

Input Power Specifications
Input voltage

12 - 15.5 volts

Maximum power consumption:
Printer is on and printing
Printer is asleep and not charging

5 Amps
.05 Amps

Note:

Connecting to voltage usage outside of the specifications will damage the printer.

12 Volt DC Jack Cable (white)

Advertising