Energy consumption display, Ab c d – DE DIETRICH ALEZIO AWHP-V220 User Manual

Page 21

Advertising
background image

2. Use the B (-) and C (+) keys to scroll through the information.

If no buttons are pressed for 10 seconds, the screen goes

back to the main display.

For permanent information display:

When the word SERVICE flashes, press the A (G) and B
(-)

keys simultaneously.

The word SERVICE continues to be displayed and no

longer flashes.

3. Press the key A (G) to exit the menu.

If the information SERVICE is not displayed, the screen will

switch back to the main display after 5 seconds.

The following data can be accessed in the information menu:

Parameter Description

Unit

pB

4

In heating mode: Heating flow set point temperature

4

In DHW mode: DHW setpoint temperature

4

In cooling mode: Cooling setpoint temperature

4

In swimming pool mode: Pool set temperature

°C

pC

Measured start temperature

°C

pD

Domestic hot water temperature measured

°C

pE

Outside temperature measured

°C

lp

Water flow

l/min

F.jp

Software version

4.4.1.

Energy consumption display

Parameter Description

Unit

gB:

Estimated consumption of electrical energy in heating mode

(1)

kWh

gC:

Estimated consumption of electrical energy in DHW mode

(1)

kWh

gD:

Estimated consumption of electrical energy in cooling mode

(1)

(2)

kWh

(1) Display available if the estimated electrical energy consumption function is activated

(2) Cooling mode must be enabled

The estimated electricity consumption is displayed in 3 digits. The

fourth digit indicates the scale (x1, x10, x100, x1000).

M

K

!

"

"

"

SERVICE

L

0

0

0

3

1

6

-A

A

B

C

D

.

E

D





AWHP-V220

4. Operating the appliance

23/04/2013 - 300026802-001-03

20