Advertising
background image

3. Vent the underfloor heating circuits and the radiators. First vent

the lower floors A and then the upper floors Z.

5.4.2.

Automatic venting

The heat pump runs an automatic venting cycle when it is powered

up. Automatic venting takes approximately one minute.

Automatic venting starts up only if the measured DHW

temperature is lower than 25°C.

It is possible to extend automatic venting manually to run for more

than one minute:
1. The word SERVICE flashes when powering up. Press A and B

(d)-keys simultaneously.
An automatic venting cycle begins. The word SERVICE stops

flashing .

2. Press the A and B (d) keys simultaneously to stop the venting

cycle.

¼Consult the installer for more detailed information.

WARNING

After venting, have the installation’s pressure checked.

Top up with water if necessary.