Checking and maintenance, General instructions, Periodic checks – DE DIETRICH ALEZIO AWHP-V220 User Manual

Page 23: 5 checking and maintenance, 1 general instructions, 2 periodic checks

Advertising
background image

5 Checking and maintenance

5.1

General instructions

CAUTION

4

An annual inspection is compulsory.

4

We recommend taking out a maintenance contract.

4

Maintenance operations must be done by a qualified

engineer.

4

Only original spare parts must be used.

4

Make certain that the flues and chimneys are

connected, in good condition and not blocked.

4

Do not modify nor block the condensate outlet(s).

4

If a neutralisation system is installed, follow the

instructions delivered with the neutralisation system

for cleaning and servicing of this system.

5.2

Periodic checks

WARNING

Only qualified professionals are permitted access to the

inside of the appliance.

If the pressure gauge is not accessible, contact the

installer.

4

Have the installation’s water pressure checked.

If the water pressure is lower than 1 bar, more water should

be added. If necessary, top up the water level in the heating

system (recommended hydraulic pressure between 1,5

and 2,0 bar).
¼See chapter: "Top up the installation with water",

page 23.

4

Carry out a visual check for the presence of any water leaks.

T001507-B

AWHP-V220

5. Checking and maintenance

23/04/2013 - 300026802-001-03

22

Advertising