6 troubleshooting, 1 breakdown codes, 1 safety alarms – DE DIETRICH ECODENS DTG 1300-24 ECO _ V-130 User Manual

Page 12: 2 sensor alarms, 3 before contacting the installer, Troubleshooting, Safety alarms, Sensor alarms, Before contacting the installer

Advertising
background image

12

DTG 1300-24 Eco / V130

11/09/09 - 300010111-001-B

6. Troubleshooting

6 Troubleshooting

In the event of a fault, the display indicates an alarm message by
alternately showing AL and a code from which the type of fault can
be determined.

6.1 Breakdown codes

6.1.1

Safety alarms

6.1.2

Sensor alarms

6.1.3

Before contacting the installer

`

Try to restart the boiler once by pressing the key Q  on the
control panel.

`

If this fails after a second try to restart,inform the professional
responsible for maintaining the boiler.

`

Note the following information on the appliance's rating plate:

- Boiler type
- Date of manufacture
- Serial no. of the appliance
- Type of gas used.

Alarm code

Meaning

cA

Igniter fault

cI

Ionization error

tS

Overheating alarm

PA

No water

cd

Communication error with the safety control box (card side)

c8

Internal error safety control box

A1

Communication error with the safety control box (box side)

TH

Communication with the communicating remote interrupted

Alarm code

Meaning

40

Fault external sensor

41

No outside sensor on start-up if outlet sensor B present

42

Fault outlet sensor B

50 or 51

Fault temperature sensor heating outlet

54 or 44

Domestic hot water outlet sensor fault

58 or 59

Fault electronic manometer

C002672-B