3. Description

3 Description

3.1 General description

ECODENS boilers are floor-standing gas-fired condensing boilers.
They are combined with a 130 litre tank to handle domestic hot water
production and central heating using radiators or underfloor heating.

The boilers can operate on natural gas or on butane/propane. They
are factory set for natural gas H.

3.2 Control panel

C000773-B

N Temperature display

The display shows the temperature of the water in the domestic hot water heating outlet when
there is a request for domestic hot water.

O Domestic hot water temperature maintenance

override button

I

With Easymatic remote control:
Pressing the button for 1 second makes it possible to override domestic hot water tank loading
outside the time period programmed in the control unit up to midnight (indicator light O2 flash).
- Light O1 lit : The burner is ignited to reheat the domestic hot water tank.
- Light O2 off : No override or programme running.
- Light O2 lit : Comfort programme activated.

P Safety shutdown light

Indicates an error in the boiler.

Q Reset button



To restart the boiler after safety shutdown.

R Button -

Used only in measurement

V

, installer

K

and sweep

M

mode.

S Button +

Used only in sweep mode

M

.

T 6-position switch

-

.

: Stop / Anti-freeze / Bleed.

-



: Domestic hot water (Summer).

-

"

: Heating and domestic hot water (Winter).

-

V

: Measurement mode (Key to access the parameters reserved for the installer).

-

K

: Fitter mode (Key to access the parameters reserved for the installer).

-

M

: Sweeping mode (Key to access the parameters reserved for the installer).

U "Heating" on light

The light is on when the heating/domestic hot water reversal valve is in the heating position and the
circulator pump is operating.

V Heating temperature setting

Setting range: 30 °C to 90 °C (Hard spot at 68°C).

W Flame presence light

The light is on when the burner is operating.

X Setting the domestic water temperature

Setting range: 40 °C to 60 °C (Hard spot at 55°C).

Y "Domestic hot water" on light

The light is on when the heating/domestic hot water reversal valve is in the domestic hot water
position and the circulator pump is operating.

Z Pressure indicator

Indicates the pressure in the heating circuit from 0.5 to 2.5 bar.