6.1 Table of "User" setting

The different adjustable parameters are listed in their order of
appearance.

At the end of the intervention, the data is memorised after 2 minutes
or by pressing the AUTO key.

Display

ROE-II ROE-H ROE+ ROE+TH SOLO,

NAPO

ROI+

Parameter set

Factory

setting

Adjustme

nt range

#MEASURES

Allows the values below to be read

TEMP.MIT

x

x

x

x

x

x

Water temperature in the MIT-II module or
heating zone in the Quadro

-

-

HP FLOW TEMP.

x

x

x

Water temperature at the PAC outlet

-

-

SOURCE TEMP.

x

Refrigerant temperature at the heat pump source
end

-

-

COLD TEMP.

x

x

Temperature of the PAC cold circuit

-

-

EVAPORATOR T.

x

Refrigerant temperature at the fin tube
exchanger outlet

-

-

OUTLET TEMP. B*

x

x

x

x

x

Water temperature in circuit B (Flow sensor)

-

-

WATER TEMP. *

x

x

x

x

x

Tank water temperature

-

-

ROOMTEMP. A*

x

x

x

x

x

Room temperature A

-

-

ROOMTEMP. B*

x

x

x

x

x

Room temperature B

-

-

OUTSIDE TEMP.

x

x

x

x

x

Outside temperature measured by the MIT-II
module

-

-

HP RETURN TEMP

x

x

Return temperature

-

-

HP FLOW TEMP.

x

x

Flow temperature

-

-

FLUID EVAP.T.

x

x

Fin tube exchanger refrigerant temperature

-

-

FLUID COND.T.

x

x

Refrigerant temperature at the heat exchanger

-

-

HOT GAS TEMP.

x

Refrigerant temperature at the compressor outlet

-

-

HP OUTSIDE T.

x

x

x

x

Outside temperature measured by the PAC

-

-

HP FLOW TEMP.

x

Water temperature at the PAC outlet

-

-

HP RETURN TEMP

x

Return temperature

-

-

HP AIR IN T.

x

Outside temperature at the heat pump

-

-

EVAPORATOR T.

x

Refrigerant temperature at the fin tube
exchanger outlet

-

-

HOT GAS TEMP.

x

Compressor outlet temperature

-

-

PRESSION(BAR)

x

x

x

x

x

x

Water pressure display

-

-

NB IMP.COMP.

x

x

x

x

Number of PAC start-ups

-

-

NB IMP.COMP.1

x

Number of start-ups on compressor 1

-

-

RUNTIME COMP.

x

x

x

x

x

x

Number of PAC operating hours
Number of hours' operation of compressor 1

-

-

NB IMP.COMP.2

x

Number of start-ups on compressor 2

-

-

RUNTIME.COMP.2

x

Number of hours' operation of compressor 2

-

-

CTRL

x

x

x

x

x

x

Information reserved for the technician (Diematic
programme version)

-

-

* The line or title is only displayed for the options, circuits or sensors actually connected

.