2 display – DE DIETRICH MIT-II-E, MIT-II-H, MIT-EP, MIT-HP and QUADROPAC DUP 500 User Manual

Page 5

Advertising
background image

5

14/04/2010 - 300015090-001-L

MIT-II - MIT/P - QUADROPAC DUP 500

3.2 Display

0

2

4

6

8

10

12

14

16

18

20

22

24

A

bar

3

4

5

6

7

9

10

11

8

2
1

B C

SUNDAY

1

Text and numerical display

2

Graphic bar displaying the programme on circuit A or B (in
zone 9)

3

Light area: Nighttime period

4

Dark area: Daytime period

5

Flashing cursor showing the current time

6

Number display (current time, adjusted values, parameters,
etc.)

7

Active programme display, P1, P2, P3, P4
or
E: Summer mode activated - heating OFF

8

Flashing arrows when the

or



keys should be used to

adjust the displayed parameter

9

Circuit operation symbols

>

Opening the 3-way valve

=

Closing the 3-way valve

:

Displayed circuit pump on

A, B

Name of the circuit displayed

10

Symbol displayed above the active operating mode

11

Symbols indicating that the following inputs/outputs are
active
ROE-II - ROE+ - SOLO - NAPO - ROI+ - ROE-H

D

PAC is operating in Hot or Cold mode

X

PAC is operating in Hot mode with additional electrical heating
at stage 1

Y

PAC is operating in Hot mode with additional electrical heating
at stage 2



Additional electrical heating operating, stage 1. PAC off

Additional electrical heating operating, stage 2. PAC off



DHW production pending with the thermodynamic unit

#

Forced "summer" condition

ROE+ TH

D

PAC is operating in Hot mode with 1 compressor

E

PAC is operating in Hot mode with 2 compressor

X

PAC is operating in Hot mode with 2 compressors and 1 back-
up provision

Y

PAC is operating in Hot mode with 2 compressors and 2 back-
up provision



Additional electrical heating operating, stage 1. PAC off

Additional electrical heating operating, stage 2. PAC off



DHW production pending with the thermodynamic unit

#

Forced "summer" condition

Water pressure display, user interface

Insufficient pressure: add water (0 - 0.5 bar)

U

Addition of water recommended (0.5 - 1 bar)

T

Pressure correct (1 - 2 bar)

Too much pressure (> 2 bar)

Advertising