1 heating temperature setting, 2 dhw set temperature, Heating and domestic hot water temperature setting – DE DIETRICH MIT-II-E, MIT-II-H, MIT-EP, MIT-HP and QUADROPAC DUP 500 User Manual

Page 9

Advertising
background image

9

14/04/2010 - 300015090-001-L

MIT-II - MIT/P - QUADROPAC DUP 500

4 Heating and domestic hot water temperature

setting

4.1 Heating temperature setting

The comfort and reduced temperatures are set separately for each
circuit:
- Select the comfort temperature or the reduced temperature for the

desired circuit by successively pressing key

2%

or

2$

.

- Set the temperature using keys

and



.



The graphic bar displays the heating programme for the
displayed circuit for the current day.

End of setting: Press the AUTO key or after 2 minutes.

* Is displayed if the following 2 conditions are satisfied:

- at least one room sensor is connected on a circuit which is

configured in underfloor heating (FL.HE.),

- cooling mode on.

• In summer mode, when the room temperature measured by the

sensor is higher than the set point ROOM REFR.T., the cooling
mode starts up. The cooling mode shuts down when the room
temperature measured is lower than ROOM REFR.T. -0.5°C.

• In parallel, depending on the outside temperature, automatic

cooling remains on.

4.2 DHW set temperature

- Select the domestic hot water temperature using key

2

and

set the temperature using keys

or



.



If there is no domestic hot water sensor, pressing this key has
no effect.

- End of setting: Press the AUTO key or after 2 minutes.



If DHW consumption is high, increase the domestic hot water
set temperature to 60°C.

2%

Comfort temperature - Cooling

2$

Reduced temperature

2

Domestic hot water temperature

0

2

4

6

8

10

12

14

16

18

20

22

24

A

C000142_02

SUNDAY

-04

Temperature

2

Factory setting

Adjustment range

%

DAY TEMP. A

20 °C

5 to 30 °C
In steps of 0.5°C

ROOM REFR.T. *

25 °C

22 to 30 °C
In steps of 0.5°C

$

NIGHT TEMP. A

16 °C

5 to 30 °C
In steps of 0.5°C

Temperature

Adjustment range

Factory setting

Domestic hot
water

2

10 to 80 °C
In steps of 5°C

55 °C

Advertising