3 incidents and solutions, The burner is not working, The burner is operating but the radiators are cold – DE DIETRICH GTU C 330 User Manual

Page 20

Advertising
background image

20

GTU C 330

24/11/08 - 300017846-001-B

8. Troubleshooting

8.3 Incidents and solutions

„

The burner is not working:

`

Check the boiler thermostat settings.

`

Carry out the checks mentioned in the burner instructions.

`

Shutdown by the safety thermostat due to accidental
overheating:

Boiler: Check that the safety thermostat has not triggered. To

restart the boiler, reset the safety thermostat. Remove the safety
thermostat hood and press the reset button with a screwdriver.

Condenser: Check that the safety thermostat has not triggered:

- Unscrew the protection cap
- Press the resetting button of the burner

`

Carry out the start-up operations again. Call your fitter.

`

Check the circuit breaker

„

The burner is operating but the radiators are cold:

`

Bleed the radiators.

`

Checking the hydraulic pressure. The hydraulic pressure must
be a minimum of 0.8 bars. Adjust the pressure if necessary,
avoiding a sudden influx of cold water into the boiler when it is
hot.
If it is often necessary to top up the installation with water,
contact your fitter.

`

Check that the heating pumps are working correctly

`

Check the position of the 3 position switch.
Control panel B3: TEST-STB/

.

/

%

on

.

.

Control panel DIEMATIC-m3: AUTO/

!

/TEST STB on

AUTO.
Control panel K3: AUTO/

!

/TEST STB on AUTO

`

Check the settings on the boiler thermostat(s).

C001951

1

2