Brooks Instrument MT3809G User Manual

Page 45

Advertising
background image

Installation and Operation Manual

X-VA-MT3809G-MT3810G-eng
Part Number: 541B182AAG
September, 2013

Models MT3809G & MT3810G

3-7

Section 3 Operation

3-4 Operation of the Model MT3809 Flowmeter with a Transmitter and Inductive Alarms (1 or 2 switches)

a. Start-up the meter as described in Section 3-2.
b. Start-up the transmitter as described in Section 3-3.
c. Start-up the inductive alarms as described in Section 3-6.

3-5 Operation of the Model MT3809 Flowmeter with a Transmitter and Display

The output of the 4-20 mA transmitter drives the LCD display option. The
LCD display is a three line liquid crystal display. It can easily be
programmed to provide basic information such as flow rates and product
totalization. Configuration adjustments to upper/lower range values can
also be performed using the display. Access to the display can be
accomplished by removing the cover or by using the supplied magnet with
the cover in place. Refer to Figure 3-3 for the menu tree for more details.

3-6 Operation of the Model MT3809 Flowmeter with Inductive Alarms (1 or 2 switches)

a. Start-up the meter as described in Section 3-2.
b. To modify the alarm set points, remove the front cover with gasket of the

indicator housing by removing the four screws.

c. Set the alarm position by loosening the two pointer screws, moving the

pointer to the desired alarm setting and tightening the screws.

d. Replace the indicator housing cover with gasket and secure with the four

screws.

Advertising