Cleaning 10.4. recommended auxiliary materials, Repairs, Replacing the valve set – Burkert Type 2000 User Manual

Page 15

Advertising
background image

15

Repairs

10.2.2. Angle seat valve

Parts which are subject to natural wear:
• Pendulum disc
• Graphite seal
If leaks occur, replace the particular wearing part with an appro-
priate spare part (see Chapter "13. Spare parts").

10.3. Cleaning

Commercially available cleaning agents can be used to clean the
surface of the device.

NOTE!

Avoid causing damage with cleaning agents.
• Before cleaning, check that the cleaning agents are compatible

with the housing materials and seals.

10.4. Recommended auxiliary materials

In this manual the following auxiliary materials are recommended for
faultless operation, maintenance and repair of the device:

Type of aux-
iliary material

Product
designation

Manufacturer and Internet
address

Lubrication
paste

Klüber paste
UH1 96-402

Klüber Lubrication München KG,
www.klueber.de

Adhesive

Loctite 640

Marketing Loctite, Henkel AG &
Co.KGaA,
www.loctite.de

11. REPAIRS

CAUTION!

Risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries
and damage the device and the surrounding area.
• Use original accessories and original spare parts from Bürkert

only.

11.1. Replacing the valve set

The valve set consists of:
• The pendulum disc:

consisting of - Seal holder

- Seat seal
- Centering

• The graphite seal

This can also be ordered separately

Before the valve set can be replaced, the actuator must be
removed from the valve housing as described below.

english