9

Technical data

6.4. General technical data

6.4.1. Inscription on the rating plate

Flow 1 2
2000 A 10,0 PTFE VA

Made in Germany

00182076

W1X LU

G3/8 P

med 16 bar

Pilot 5,5 - 10 bar

Direction of flow

(1 and 2 = identification of the

connections on the valve housing)

Type, operating principle, orifice,

seal material, housing material

Identification number

Manufacturer code

Permitted control pressure range

Connection type,

permitted max. medium pressure

Example:

Fig. 2:

Example of rating plate

6.4.2. Materials

Valve housing

stainless steel 316L

Actuator

stainless steel 1.4404

Sealing elements

FKM

Spindle sealing

PTFE-V rings with spring compensation

(with silicone grease)
Seat seal

PTFE

Spindle

stainless steel 1.4401/1.4404

6.4.3. Connections

Control air connection

45° hose plug-in connection 4/2 M5

(recommendation)

order no. 903383

Medium connection

G3/8 and NPT3/8 socket connection
G1/2 external thread
Welded spigots according to
EN ISO 1127/ISO 4200, DIN 11850
Series 2, ASME BPE. Other connections
on request

6.4.4. Installation position

Any position, preferably with the actuator face up.