Menu (see chapter 12.4, See chapter 12.4 – Burkert Type 8611 User Manual
Page 59

59
FunctionsoftheConfigurationLevel
12.4.
UNIT - selection of measuring units and decimal
places
In this menu option, the measuring units and the number of decimal places (see Table 20) are selected for the
displayed values.
What measuring unit is selected in the
UNIT menu depends on the control variable set in the MODE
menu.
Selecting the measuring unit and decimal places in the menu:
selected control variable
MODE = RATI
Liters/minute
Gallons/hour
Gallons/minute
Milliliters/minute
Cubic meters/hour
Liters/hour
SETP
RFAC
UNIT
L / M
G / H
G / M
ML / M
M3 / H
L/H
1
DP F
0.1
DP F
0.01
DP F
selected control variable
MODE = P
Bar
Millibar
PSI (American measuring unit)
BAR
MBAR
Q1
Q2
PSI
1
DP_P
0.1
DP_P
0.01
DP_P
selected control variable
MODE = F,
Figure 44:
UNIT; Selecting the measuring unit and decimal places for control variable MODE = RATI,
MODE = F, MODE = P
english
Type 8611