English, 3 explosion protection – Burkert Type 1094 User Manual

Page 15

Advertising
background image

1094_400 - 13

english

The self adaptation set MKEN-1094 is used to control the gas stations with
vapor recovery and to adjust the Bürkert control. Only the gas meter is located
in a hazardous location if the self adaptation set is used properly (Figure 12).

5.3

Explosion protection

Legend:

1

Hand held terminal

2

Gas meter

3

Dispensing nozzle (with adapter)

4

Dispenser

5

Proportional valve

Figure 12: Hazardous locations at the gas station

The current circuit from the hand held terminal to the gas meter is intrinsic
safety due to the fitted safety barrier. Therefore it can be used in the
hazardous area zone 1.

ATTENTION!

Due to safety reasons, the gas meter must be connected
before the nozzle. We do not accept any liability for damage
as a consequence of incorrect connection of the flow meter.
Note:
In order to ensure a long service life of the gas meter,
gasoline must not enter the gas meter under any
circumstances.

6

Vacuum pump

7

Operating motor for the vacuum
pump

8

Storage tank

9

Simulation tank