English – Burkert Type 1094 User Manual

Page 35

Advertising
background image

1094_400 - 33

english

Input

Selection Remark

Select position
Select number

Select line 1-4
Select position 1-16
Select number

Yes / No

Return to display mode

ENTER

ENTER

ENTER

ENTER

Display (2-lines)

Time
TEST

08:45

BUERKERT
TEST

Line 1

Print

?

TEST

Yes

Fuel flow
ACT.

00,0 l/min

Testing the Vapor Recovery System

Wet Measurement Foreign Product

Dispenser No.

01

Product:

BF95

T amb:

24,0 Grad C

Fuel volume:

25,0 l

Vapor volume total:

25,0 l

Recovery rate:

100 %

Place:

Date:

21.08.97

Time:

08:45

Signature:

Buerkert GmbH
Postfach 20
D-74653
Ingelfingen

Print out:

Advertising