1094_400 - 27
english
Display (2-lines)
V4.1
Operator?
INIT
CHECK-
1094
Fuel flow
ACT.
40,0
l/min
Vapor flow Max
TEST
46,0
l/min
Vapor flow 40
TEST
44,0
l/min
C-factor
40
TEST
110
%
Recovery rate 40
TEST
110
%
Corr. VR
40
TEST
100
%
Vapor flow 40
ACT.
44,0
l/min
6.6.3 Test Mode Evaluation, Service und Check-1094
Input
Selection
ENTER
DATA
Remark
Selecting the operator mode
Display mode
Vapor flow
Vapor flow
Correction factor
Recovery rate
Correct Recovery rate
Return to display mode
DATA
DATA
First the maximum Vapor flow is established. After this the simulation of the fuel
flow starts. It begins with 40 l/min is changed by pressing the keys
The simulated fuel flow is displayed in the upper right corner.