Burkert Type 8681 User Manual

Page 86

Advertising
background image

86

Replacement of Components and Modules

Loosen the electronics module's fastening screw (Torx 10) (see chapter

→

19.2. Changing the Electronics

Module).

Tilt the electronics forwards to loosen the position measuring system's contact pins from the electronics module.

→

Bend the snap-fit hooks on the bottom end of the position measuring system inwards. In some cases, break

→

them off.

Pull the position measuring system upwards out of the guide.

→

installation procedure:

Insert the new position measuring from above so that the contact pins are located on the side of the elec-

→

tronics module.

Carefully push the housing of the position measuring system downwards until the snap-fit hooks snap into

→

place.

Slide the electronics module carefully onto the contacts pins and fasten the electronics module using the Torx

→

screw.

Remount the control head on the process valve as described in chapter

→

7. Installation.

Adjust position measuring system to the process valve by teaching (see chapter

→

15.1. Setting the Position

Measuring System (Teach-In))

Close the housing observing the notes contained in chapter "

→

8. Opening and Closing the Housing".

english

Control Head Type 8681

Advertising