Electrical data – Burkert Type 8020 User Manual

Page 5

Advertising
background image

16

downstream distances respected, appropriate pipe dimensions

Tab. 2:

Dimension H [mm] of the 8020 depending on
the DN of fitting S020

H

T fitting

Saddle

Spigot, in
plastic

Welding
tab with
radius, in
stainless
steel

DN20

153.5

DN25

153.5

DN32

157.0

DN40

161.0

DN50

167.0

191.5

162.5

DN65

167.0

190.5

172.5

167.0

DN80

194.5

177.5

173.0

DN100

199.5

184.0

183.5

English

17

H

T fitting

Saddle

Spigot, in
plastic

Welding
tab with
radius, in
stainless
steel

DN110

195.5

DN125

202.5

194.5

DN150

212.5

230.0

205.5

DN180

236.5

DN200

248.5

251.0

226.0

DN250

269.0

286.0

DN300

280.5

305.5

DN350

294.0

317.5

DN400

308.5

English

17

18

191 mm

153 mm

75 mm

Fig. 1: Dimensions [mm] of the flowmeter 8020

materials

Part

Material

Housing

PE

Nut

PC

Female connector type

2508 / screw / seal

PA / Stainless steel / NBR

Frame of the flow sensor

and paddle wheel

PVDF

English

19

Part

Material

Axis and bearings

Ceramic

Gasket

FKM (EPDM optional)

electrical data

Supply voltage

• Hall version

• Hall Low Power

version

• 12-36 V DC, filtered and

regulated

• 12-36 V DC, via transmitter the

device is connected to

Current
consumption

• Hall version
• Hall Low Power

version

• 50 mA max.
• 0,8 mA max.

Protection against
polarity reversal

yes

Protection against
spike voltages

yes

Protection against
short circuits

yes

English

19

Advertising