Burkert Type 8020 User Manual

Page 6

Advertising
background image

20

Transistor output
(Hall version)

pulse output, NPN and PNP, open
collector, max. 100 mA, frequency
up to 300 Hz, duty cycle 1/2 ±10%
NPN output: 0,2-36 V DC
PNP output: supply voltage

Transistor output
(Hall Low Power
version)

pulse output, NPN, open collector,
max. 10 mA, frequency up to
300 Hz, duty cycle 1/2 ±10%

Coil output

sine-wave signal, frequency up to
300 Hz, about 2.8 mV peak-to-peak/
Hz under a 50 kW load

English

21

electrical connection

type of connector

cable type

2508 female connector
(supplied), with order
code 438811

For the Hall and Hall Low
Power versions:
• shielded, max. 50 m
• 5 to 8 mm in diameter
• wires between 0,25 and

1,5 mm

2

in cross section

For the sinus version:
• shielded, max. 10 m
• 5 to 8 mm in diameter
• wires between 0,25 and

1,5 mm

2

in cross section

English

21

22

7. insTAllATion AnD

commissioninG

safety instructions

danger

risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure and

drain the pipe before loosening the process connections.

risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid, and drain the pipe before

loosening the process connections.

risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident prevention

and safety relating to the use of hazardous products.

danger

risk of injury due to electrical voltage.
• Shut down and isolate the electrical power source

before carrying out work on the system.

• Observe all applicable accident protection and safety

regulations for electrical equipment.

English

23

Warning

risk of injury due to non-conforming installation.
• The electrical and fluid installation can only be carried out

by qualified and skilled staff with the appropriate tools.

• Observe mounting instructions of the fitting.
risk of injury due to an uncontrolled restart.
• Ensure that the restart of the installation is controlled

after any interventions on it.

Warning

risk of injury if the fluid pressure/ temperature
dependency is not respected.
• Take account of fluid temperature-pressure

dependancy according to the nature of the materials

the fitting is made of (see Tab. 1).

• Comply with the Pressure Directive 97/23/EC.

English

23

Advertising