Performance characteristics of the cmu sensor, Reference conditions, Cmu flow ranges – Fluid Components International CMU User Manual

Page 15

Advertising
background image

3.4

Performance characteristics of the CMU sensor

3.4.1 Reference

conditions

•

Established flow profile

•

Inlet section has to correspond to mounting length

•

Operation is to be realized in the presence of downstream control valves

•

Measurement is to be realized in the absence of any gas bubbles

•

Flow tubes are to be kept clean at all times

•

Process temperature is to be regulated as specified in Section 3.6.1 Process temperature on
page 23

•

Process pressure is to be regulated as specified in Section 3.6.6 Process pressure range on
page 23

•

Ambient temperature is to range from + 10 °C to + 30 °C (50 °F to 86 °F)

•

Warm-up period: 15 minutes

•

Standard calibration is to be realized at 20 %, 50 % and 100 % (three times each)

•

High-frequency interference is to be regulated as specified in Section 17.2 Electromagnetic
compatibility on page 110

3.4.2

CMU flow ranges

Model

kg/h [lbs/min]

kg/h [lbs/min]

kg/h [lbs/min]

kg/h [lbs/min]

CMU-C

60 [2.2]

600 [22.0]

330 [12.1]

0.06 [0.002]

CMU-D

250 [9.2]

2,500 [91.9]

1,150 [42.3]

0.25 [0.01]

CMU-E

1,200 [44.1]

12,000 [440.9]

5,250 [192.9]

1.2 [0.04]

CMU-G

3,000 [110.2]

30,000 [1,102.3]

20,000 [734.9]

3 [0.1]

CMU-H

6,000 [220.5]

60,000 [2,204.6]

55,000 [2,020.9]

6 [0.2]

CMU-J

20,000 [734.9]

80,000 [2,939.4]

74,000 [2,719.0]

8 [0.3]

CMU-K

25,000 [918.6]

120,000 [4,409.2]

118,000 [4,335.7]

12 [0.4]

CMU-L

30,000 [1,102.3]

200,000 [7,348.6]

200,000 [7,348.6]

20 [0.7]

CMU-N

60,000 [2,204.6]

460,000 [16,901.8]

460,000 [16,901.8]

46 [1.7]

CMU-P

150,000 [5,511.5]

700,000 [25,720.2]

700,000 [25,720.2]*

70 [2.6]

CMU-Q

300,000 [11,022.9]

1,500,000 [55,114.6]

1,350,000 [49,603.2]

150 [5.5]

CMU-R

400,000 [14,697.2]

2,200,000 [80,834.8]

1,900,000 [69,811.9]

220 [8.1]

* (

⎠ p=0,6bar)

Zero point stability

(of range)

Max.

measuring range

Nominal

(

¬p=1bar)

Mass flow

Min.

measuring range

Reference conditions: in conformity with IEC 770:
Temperature: 20 °C, relative humidity: 65 %, air pressure: 101.3 kPa
Fluid: water

CMU & CT OPERATING MANUAL
Part No 06EN003380 rev 1.6

Page 15 of 112