Leaning, Rain, Alve – GeneralAire DS20 Elite Steam User Manual

Page 19: Ydraulic, Arts, Installation, operating and maintenance manual

Advertising
background image

Installation, Operating and Maintenance Manual

Cleaning The Drain Valve

Remove the drain valve group and disassemble it.
Clean all parts in the same way as the fill valve,
reassemble and reinstall.

After cleaning and reassembly, restart your humidifier
according to the Startup Instructions contained in this
manual.




Hydraulic Parts

No.

Description

1 Fastening o-ring for s/d (supply - drain)

manifold

2 Supply/drain

manifold

3 Water fill valve
4 Drain

valve

5 Fill cup supply hose
6 Cylinder supply hose
7 Overflow hose
8 Fill cup with conductivity probes
9 Base / drain pan

See spare parts list on page 20


Clean the drain pan and fill cup of any deposits and check
that the water flows freely from the fill cup to the drain.

Check that there are no blockages or solid particles and
that the conductivity measuring electrodes are clean.
Remove any impurities and rinse.

19