Ad2050, Megapower lt, Megapower 48 – American Dynamics RAS916WLS User Manual

Page 77: Megapower 1024

Advertising
background image

AD2050

Supported Protocol

RS-422

(1)

Maximum Presets

16

(2)

or

60

(3)

Maximum Patterns

(4)

3

Quick Set Menu

Not supported

Address Range

1-1024

(5)

Notes:

(1) Requires the AD2083-02 series code converter.

(2) Preset information is stored at the converter, not the

dome.

(3) Requires AD2083-02 with firmware version 0701-11YB-

156A or newer. Preset information is stored in the
dome, not the converter.

(4) Patterns are limited by time and the number of available

dome commands. Total time for each pattern cannot
exceed 6 minutes 50 seconds. Total dome commands
used in all patterns cannot exceed 99.

(5) Requires additional equipment to achieve these

numbers. A dome address within each group of 64 or 99
cameras is reserved as a global broadcast address.

MegaPower LT

Supported Protocol

SensorNet

Maximum Presets

96

Maximum Patterns

(1)

3

Quick Set Menu

Yes

(2)

Address Range

1-32

Notes:

(1) Patterns are limited by time and the number of available

dome commands. Total time for each pattern cannot
exceed 6 minutes 50 seconds. Total dome commands
used in all patterns cannot exceed 99.

(2) Requires a compatible keyboard.

MegaPower 48

Supported Protocols

SensorNet

RS-422

Maximum Presets

96

(1)

Maximum Patterns

(2)

3

Quick Set Menu

Yes

(3)

Address Range

1-48

Notes:

(1) Preset information is stored at the host, not the

dome.

(2) Patterns are limited by time and the number of

available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds.
Total dome commands used in all patterns cannot
exceed 99.

(3) Requires firmware 1.07 or newer and a compatible

keyboard.

MegaPower 1024

Supported Protocol

RS-422

(1)

Maximum Presets

16

(2)

or

60

(3)

Maximum Patterns

(4)

3

Quick Set Menu

Not supported

Address Range

1-1024

(5)

Notes:

(1) Requires the AD2083-02 series code converter.

(2) Preset information is stored at the converter, not

the dome.

(3) Requires AD2083-02 with firmware version 0701-

11YB-156A or newer. Preset information is stored
in the dome, not the converter.

(4) Patterns are limited by time and the number of

available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds.
Total dome commands used in all patterns cannot
exceed 99.

(5) Requires additional equipment to achieve these

numbers. A dome address within each group of 64
or 99 cameras is reserved as a global broadcast
address.

SensorNet and RS-422 Protocols Command Summary

A–5

Advertising